Name |
) |
| Picture |
|
Introduce |
Function features:
★
Two-way measure single-phase AC active electric energy
★ One
merter with one card
★
Control
load
★
Warning
when residual energy is deficient
★
Credit
for emergencies
★
Need not a battery, the data can be stored for more than 10 years
after the electricity goes off
★
Can be customized according to user needTechnical
parameter:
★
Standard: GB/T17215-2002、GB/T18460-2001
★
Accuracy class: 1.0 class, 2.0 class
★
Rated voltage: 220V
★
Rated current: 5(20)A、5(30)A、10(40)A
★
Meter's Constant: 1600imp/kWh, 3200imp/kWh
★
Rated frequency: 50Hz
★
Electric parameter:
Normal operating voltage: 0.8~1.1Un
Limited
operating voltage: 0.7~1.15Un
Isolation voltage: ≥2000VAC
Power
Consumption: ≤1W and
10VA
★ Operating
conditions:
Normal
operating temperature: -20℃~45℃
Limited
operating temperature: -25℃/45℃~55℃(must make to order when temperature is lower
than -45℃)
Relative
humidity: ≤75%
★
Physical features:
Size:
172mm×108mm×60mm(Type A)
Weight:
about 0.75kg
Size:
187mm×127mm×59mm(Type B)
Weight:
1.1kg
|
Name |
) |
Picture |
|
Introduce |
Technical
parameter:
★
Two-way
measure single-phase AC active electric energy
★
One
merter with one card
★
encrypted/CPU card for
choice
★
Control
load, automatic trip if overload, resume after the card is inserted
★
Warning
when residual energy is deficient
★
Credit
for emergencies
★
Can
choose to install RS485 interface
★
Can
choose to install multi-tariff function
★
Need not a battery, the data can be stored for more than 10 years
after the electricity goes off
★
Can
be customized according to user needTechnical
parameter:
★ Standard:
GB/T17215-2002、GB/T18460-2001
★
Accuracy class: 1.0
class 2.0 class
★
Rated voltage: 220V
★
Rated current:
Type A: 5(20)A、5(30)A、10(40)A
Type B: 10(60)A、20(80)A
★
Meter's Constant: 1600imp/kW.h、3200imp/kW.h
★
Rated frequency: 50Hz
★
Electric parameter:
Normal operating Voltage: 0.8Un~1.2Un
Limited operating voltage: 0.7Un~1.3Un
Isolation voltage: ≥2000VAC
Power
Consumption: ≤1W and 10VA(Do not display on the LED)
★ Operating
conditions:
Normal
operating temperature: -20℃~55℃
Limited
operating temperature: -25℃~65℃
Relative humidity: ≤75%
★
Physical features:
Size:
172mm×108mm×60mm(Type A)
Weight:
about 0.75kg
Size:
187mm×127mm×59mm(Type B)
Weight:
1.1kg
|
Name |
Infrared card meter with 6 LED |
Picture |
(Infrared Remote Control Card) |
Introduce |
Function
features:
★
Two-way
measure single-phase AC active electric energy
★ Infrared
remote control card
★
Control
load, automatic trip if overload
★
Warning
when residual energy is deficient
★
Credit
for emergencies
★
Need not a battery, the
data can be stored for more than 10 years after the electricity goes off
★
Can
be customized according to user need
★
Remotely infrared control to write card, purchase power etc.
Technical
parameter:
★ Standard:
GB/T17215-2002、GB/T18460-2001
★
Accuracy class: 1.0 class, 2.0 clase
★
Rated voltage: 220V
★
Rated current: 5(20)A、5(30)A、10(40)A
★
Meter's Constant: 1600imp/kWh, 3200imp/kWh
★
Rated frequency: 50Hz
★
Electric parameter:
Normal
operating Voltage: 0.8Un~1.2Un
Limited operating voltage: 0.7Un~1.3Un
Isolation voltage: ≥2000VAC
Power
Consumption: ≤1W and 10VA(Do not display on the LED)
★ Operating
conditions:
Normal
operating temperature: -20℃~55℃
Limited
operating temperature: -25℃~65℃
Relative humidity: ≤75%
★
Physical features:
Size:
172mm×108mm×60mm
Weight:
about 0.75kg |
|
|
|
|